Another check to do is to place the multiport valve on recirculate, which bypasses the filter, and will let you know for sure that the problem is in the filter sand. Home / Pool Equipment / Pool Heaters & Heat Pumps / Hayward Pool Heater Troubleshooting. Test to see if 120V (+/- 10%) is coming into the motor, on the two wire terminals. It could also be an obstruction in the exhaust, like a birds nest in there, blocking the air flow from the fan. Tighten in a Pattern (tighten up the bolts in a N, S, E, W, or 12, 6, 9, 3 pattern). I think you need two timers, usually, unless it can deliver 240 to the filter pump and 120 to the booster, at the same time. We dont have mechanical time clocksit is all digital. If the pump is not grounded correctly, might that have something to do with it tripping? If your motor is overheating, and shutting off (from the thermal overload switch, located in the back, at 12 oclock), then you have some motor issues, maybe blocked air vents, broken internal fan, or a short across the windings. Another piece of information is that the board was replaced back around May of this year as well as the flow sensor. Shock the pool first and overfilter, before pulling pump. There is not much that can be done to increase flow rates for a smaller pump, with exception to reducing plumbing restrictions with larger pipe size and less elbows, etc. Maybe thats off. Hi LInda, humming or buzzing, and not starting could be a few things first check that the shaft is spinning, either by spinning on the impeller end, or at the rear of the motor (power Off in both cases), to be sure the shaft is not bound up or seized. You must log in or register to reply here. I dont see that code listed. If it is a union valve, cream also on the union nut. Anyway, have you checked the cleaner line strainer? Salt chlorine generators are great products. Finally, in cases of very hard water, some of your sand bed may have calcified, and need to be replaced. A local motor shop could probably fix you up for $100, if you can remove the pump, and drive it to their shop. Inspect for any damage to wires or wire casing. Does that have to be over the two spades or one? http://www.inyopools.com/blogSHOP at our online store! Hi Carlos, Im not familiar with working on those timers, a built-in to the back cover for Power-Flo pumps. Note: Antimicrobial properties are built in to the blue filter media to inhibit the growth of bacteria that may affect this product. If the salt cell is clean but the salt reading is off, the Aqua Rite will need to be recalibrated. I used electrical tape so the impeller In a Quirked world where most people have a superpower-like uniqueness to them, His is among the most dangerous. Not usually related to a tripped GFI, but I suppose they could be linked. Nick, it could be the capacitor, I guess water got on the terminal board, to trip the breaker. Pump motors are not normally on a GFCI breaker, unless your pump plugs in to an outlet. Help. I have a new pump and brand new grid inside my filter i have no leaks after about 10 minutes my jets stop i back wash filter and it works for about 10 min again i am stumped. Its just a trickle (as opposed to a spray)at this time. Can it be repaired or do we need a new pump? 1. Hi Joe, the Perflex DE filter has a few dozen flex tubes covered in a mesh fabric. I have a Hayward pump making more of a rattling sound inconsistent in nature. "name": "Davy Merino",
Hi, Recently when power came on it hums and shuts down after 6 seconds. Now if you do find power at the motor, and the wires are screwed tightly, but no sound, no movement, and the breaker doesnt trip it could be a bad motor. Pump cavitation produces a lower pitched gravely sound, caused by the pump being starved for water from closed valves or clogged lines or clogged impeller. Too bad Hayward doesnt make this more clear on their installation instructions and labeling. Or backwash extra long, 4-5 minutes. ), it could be a bad breaker, they can fail or become too sensitive with age. "logo": {
There is also a leak somewhere in the system because there is water on the pad. Lighting, Learn About Suggestions? The small filter, usually at the wall? After just a few minutes the flow slows down to almost nothing. All-In-One Sanitization But the process seems to take way too long. Hi Phil, hmmm, could be a breaker that is going bad they tend to wear out after 20 years or so, especially if they are used often, as a switch. If you can, you can check voltage with a meter, on the breaker, to see how much voltage it is passing. Filter primes and runs great with no air bubbles try to let it run all night to get ready for season. If I let it sit I can turn it on again, but just for about 20 seconds. Pump lid not on tight enough If the problem continues after fixing the problems above, you may have a clog in the suction side of your pump. Just replaced the sand and cleaned the fingers, replaced the o rings and have a psi of 15 and great suction. It is usually set to run at high rpm early morning and that is before sun hits it. However, we are not able to remove the pump. Hi Marsha, Ive had this question a lot this year. Does it sound like the capacitor or could something else be the culprit? well, possibly it just needs to dry out. If the clock motor is dead, you can replace just the motor, but most people replace the entire mechanism. A spike below 100V or above 140V, could blow a capacitor. Its not raw gas, but a sour smell. Overheating pumps are usually DOA, in my experience, but there may be hope. Then, I tried plugged the pump into another power outlet and it still does not work. On the return side, after the heater, the return valve should also move, with Spa Jets fully open and pool returns fully closed. Hi Tony, there could be a short in the motor, or loose wires connecting to the capacitor, or if the capacitor you are replacing with is not the correct capacitor, or if the centrifugal or stationary switches are not releasing the capacitor, due to loose or misaligned switches, or loose wires, or wires shorting out by touching other wires or the motor casing, or crimped wires give a good look around the back of the motor, and try another capacitor, maybe call Hayward and ask for the correct capacitor MFD number for your horsepower of Northstar. that is correct, those are the usual suspects. Sometimes this can be cleared or removed, without pulling the pump apart, which is def. I had my hayward pump serviced because it was making a sweeping sounda overheatng and kept shutting of after an hour . The main panel feeds a Tork timer, which I dont use the timer, I disconnected the timer motor. That is the black cylinder in the rear of the motor, located at 9 oclock. They dont usually begin to flow like a gusher, but a steady trickle. GFCIs are sensitive, but for a reason. If the switch does not close after the blower starts the control will go into lockout with the blower running. New pump probably not a shaft seal problem, just loose clamp band or volute bolts. No loose wires or insect infestation. Came out tonight and flipped the switch and pump started. Check all connections, circuit breakers, and fuses. Inspect and clean your cell. I have a Hayward HeatPro model HP21104T. Im having an air leak problem with my pool. The breakers still seem to be working since when I turn the breaker on and the timer switch for the pump, it does send power to the pump. PDF | On Jan 1, 2009, Eduardo Keegan and others published Cognitive-behavior therapy. Spillover is just the spa filling up, and overflowing into the pool, a waterfall feature is something different, with dedicated plumbing and a booster pump usually. No pressure now. For Use With: Hayward AquaTrol Pool Chlorine Generator Brand: HAYWARD REVIEWS Q&A Powered by TurnTo Review More Purchases | My Posts There are no reviews for this item. Hi Douglas, it could be the capacitor, if youre lucky. But heaters? Dont feel that resistance when bumping. Per your article, it sounds like I need a new capacitor. Hey buddy. The pump acts like it wants to pump, but doesnt. Just wired and installed a brand new Century 1 hp pump motor on a Hayward Super pump filter, getting power to the terminals of the motor but motor does not start, shaft spins freely. If communication between the ignition board and the display board is not established within 3 s of power-up an error will be displayed. I have great circulation, but I the problem is after the pump runs for around a half hour on the filter setting it barely has any force coming out of the jet. View Details Usfitnessfinder.com. It had a non Hayward motor installed before. I have an inground salt water pool with a spa and my flow rate was low so I cleaned out everything and replaced the filters and now the flow rate seems good with one problem. This new one when turned on seems to start, and pump, but the breaker shuts off in probably less than a second. We just verified all our time settings. Calling the pool builder for warranty info, too. Have a Hayward pump for above ground pool.when I start the pump it works properly and then itll stop pumping water. No power not even a humming. If you see any damage, replace your flow switch. How to Read and Adjust the Hayward Aqua Rite SCG Operational Values. Pump motors are continuous duty, meaning that they are meant for continuous operation, it wont harm the motor, or cause it to overheat. Second be sure that you are delivering 230V (+/- 10%) and that the motor is set to accept 230V (some are reversible to accept 115V too). Hi, I have a Hayward pump and it was running my barracuda g3 just fine but it stopped hours later. i hope this helps, but I am also maybe missing something. We recently had a makeover of our backyard where we replaced the concrete with pavers and it could very well be the sands and dust (yes, I had to vacuum the pool a couple times to get it clean) that got into the parts that helped speed up the demise of the pump. Hi Tracy, the C48 number is not the pump model, but the motor number. Does the panel just need to dry or did I cause possible damage? My first thought is that the breaker may be too small for the amount of amps needed to start each piece of equipment. Hi Carolyn, When a pump displays those symptoms, its usually an air leak or a collapsed suction hose, or a very dirty filter. ), or the valves that are before the pump. Start here Step 1: Select your pool type. I am getting a CEL code and the heater will not run. If clogged, open the pump up, and ream out the impeller vanes with a flexible wire. Thanks a lot! Flip timeclock switch on, inspect time clock motor gears (Intermatic clocks) for good timer motor, and inspect wiring from timer to pump. "@type": "Organization",
Unlike the error codes that show up on the digital screen, these problems dont show up as an error notification. "wordCount": "1194",
Initially, look into the pump/strainer housing. It hums. The pool is only 15 months old and I have not had any problems since getting it installed May 2017, other than a small water leak coming from the non suction side of the pump. When I try to turn on high speed it sounds like its jamming and then the breaker trips. I have a Hayward pump that will backwash but nothing else. Next, check continuity from lead to lead. I can see the water trickling in to the filter after a while, and the output becomes very limited. Use Teflon pool lube on the pump lid o-ring, reapply every 4 months. If the capacitor is bulged or cracked, or looks like it is burned or charred, you can assume that it is D.O.A. 4. remove rear motor cover, loosen screw that holds capacitor (9 oclock) and move it out of the way, so you can fit a 7/16 wrench on the rear of the motor shaft, behind the centrifugal switch. Is it problem of filter ? Maybe a complete reboot at the circuit breaker could be the answer, or a reset on the pump control panel. Mine is doing same thing. Shut it off & starting looking for help online. Turned it off and now it makes the grinding noise and turns off itself. Fourth, bad capacitor on the motor? Greetings! Ohms reading should be between 0.5 and 1.0 ohms max. Thanks! Ive read online it is most liked a valve that is faulty in some way. The idea is to cut the pipe above the pump, and crank the fitting 1/2 turn tighter, to open the crack, pump it full of superglue and then quickly unthread the pipe out of the pump, at which point the crack will close up, and hopefully seal up. If your previous pump was also 230V, as it likely was Im not sure what could be the problem, probably not a bad pump, but maybe some wire is disconnected, from the terminal board to the capacitor, for example, or otherwise mis-wired, internally perhaps? Ive replace the salt cell, circuit board, and flow switch and my Acurite is still reading high salt. Hi, I have a H250PED2. Whats that part called in case I do break it? I have a Haywood swim pro voyager and it is making a loud vibration noise. Either the pump lid oring is missing, or the lid (cover) is not tight, or a loose threaded pipe coming into the pump, or leaky valves (skimmer, main drain) air leaks are always in front of the pump. Directions say to hold motor end of shaft with wrench and to turn impeller counterclockwise (by hand). It just started leaking at the top plumbing connection. I can turn the switch to low and it will start and run then switch to high. Turned everything off, let the motor cool off and tried again. Write Review Hayward AquaTrol HP Main PCB | GLX-PCB-TROL-HP $375.97 Quantity $17.35 / Month * Platinum Preferred Manufacturer Proposition 65 Warning RPS. Would this make the breaker flip? Pull out the pump basket and reach back thru the volute to feel the impeller with your fingertips (pump off, lol), if you feel any debris, reach in with needlenose pliers, or pull apart the pump and ream the impeller vanes with a length of wire or a small screwdriver. Just replaced our pool pump, Hayward 1 hp self priming, super pump. Second most common air leak on a Super Pump would be the incoming pipe fitting. Fourth possibility is that the other lines (skimmer or main drain) are partially clogged or valves closed, not allowing enough water to enter pump, while vacuuming. When I went out to drain water from the pool it wouldnt turn on. When the centrifugal switch is pushed flat by the spinning shaft (or with your finger [power off! News Reporter Reveals On Live TV That Shes Been Secretly Recording Dec 14, 2021. An excessive temperature difference between the two thermistors (5 F or more) or an out of bounds condition on both sensors (less than 10F or greater than 180F) will result in the error code. Check for water under the display, or in the control box area. Should I shut down my system until I can get this fixed or is it safe for the motor to continue operation? I bought a new pump thinking was something wrong with pump on off switch. You can remove the pump basket and reach back with your fingers to see if any debris can be felt in the eye of the impeller (pump Off, of course, lol). The outlet the pump is plugged into, I suppose that is a 240V outlet. Hi Paul, Ants can be a problem, when they get around motors or circuit boards, but it sounds like a pump motor problem, and could simply be a weak capacitor, in the rear of the motor (black cylinder). Is this a ground issue or something else? Any ideas why? If so, the issue would reoccur again, after vacuuming usually. You can experiment with pump RPM settings, to exceed the threshold. JavaScript is disabled. Or does the breaker need a reset? Disconnected the chlorination device, and direct connected it eliminating that. It spins easily by hand and doesnt make any noise. This one is 5 years old. Read up on it and seems it happens a lot and the motor drive needs to be replaced. Is the shaft spinning freely? Removed pump from housing- nothing in impeller spins freely. A pool guy who has since stopped operating put it in. Clean the filter cartridge well, allow it to dry fully, and then replace it back in the filter tank. It seems to be coming from the wet side of the pump the strainer housing. Does it mean the problem is on the pump itself ? In some instances, it could just be a bad breaker. I have a new fiberglass pool and ever since I operate it the pump trips the breaker in most cases overnight hours between 2 timing sessions (pump not running). I Manually turned the shaft (which was not turning freely), while the motor was humming. Motor may still be good. No lubricant is needed for spider gaskets. Replace with identical MFD number, printed on capacitor. I have a Hayward pro series filter and Hayward pump. Nothing seems to give it juice. It has been operating properly in its current setup for atleast 2 years (came with house). It seems the pump is more powerful than last year ? Hi, might have been a small clog in the pipe. If thats all ok, you may want to shut off the isolation vales, and remove the handle and lid from the multiport valve and inspect the spider gasket. It works fine otherwise, but the only way to stop it from heating up to 104 is by turning the power off to the heater. Ive been told my Hayward Vsp has been shutting itself off for low power issues, even though no power issues are present. I checked the wiring, replaced the breaker, cleaned the pump impeller, motor vents are clean. Good day everyone. Should it be very hot to touch or is this an indicator for a capacitor problem? I did the shaving cream trick and no air leak detected. Is this normal? I recently took it ofdf to install a new spider gasket and saw no obvious reason for the leak. Is there something I forgot to do? Fourth, check the motor shaft to be sure that it spins easily by hand, fifth, you can check the capacitor (for capacitance), if the motor still isnt starting. Hi Jodi, perhaps the rod is not threaded all the way into the base, or there may be debris under the rod, preventing it from going down fully. Thanks. Some controllers have a Service Mode button you push, to be able to turn off equipment at the equipment pad, as opposed to an in-house remote panel. For slide valves (aka push-pull valves), an o-ring on the bottom plunger disk has gone missing or is worn, torn or badly deteriorated. If the set screws loosen, the impeller can slide forward and contact the pump housing, and grind both the bronze housing and bronze impeller down rapidly. Occasionally, while running, it trips the breaker. What do you have the output percentage set to? Also they winterized the place where the water circulates inside the pool and it wont unscrew so we can let some of the water out and put the original piece back on. Pool heaters can be the most baffling piece of pool equipment, but if you consider the proper flow of gas, water and electric, youre sure to find a solution quickly! I have a Hayward 1.65 variable speed pump it is on a timer for high and low. Hi Sam, I suppose a dead battery (capacitor), but there would be some noise or hum, as the motor tried to start, then would trip the breaker. It's a little over 3 years old and the cell checked out fine. If any of these readings are outside limits, replace motor. The pump works and will pump out whatever water is in the line, but wont prime and suck the water from the pool. If power is reaching the box, getting past the transformer, and the fuse is good, it sounds like the main PCB is the issue. hI, the impeller ring should go small side toward the impeller, they are often marked as such. I believe there a water volume calculator, that can help us size the motor, the originally company who installed is not in business. could that be a GFCI tripping? I purchased a SP1580X15 Hayward pump July 2016 and began using it this year 2017. What am I doing wrong?? The most common cause for this is turning the valve with the pump on, or not pushing the valve handle down fully as the valve is re-positioned. And check that the stationary switch, located at 6 oclock, is also screwed in tightly, and that the tab is centered on the tab of the centrifugal switch. Capacitor or needs new motor?? Open the door and inspect for debris with a mirror and flashlight. If I prime the pump and turn it on it runs fine but when I turn it off and let it set for a few minutes you can hear it cheering then the water in the pump evacuates and there appears to be some water coming from the bottom of the pump. Thanks for the help. hayward super pump C48L2N134B1. Perhaps it could be flow related, if the pump is cavitating or starved for water like if you only have 3/4 or 1 pipes (?). If they are within range, replace drive. Missing push-pull valve o-rings, DE powder getting inside of the grids however thats something notable and the fact that it only does it on Low Speed, also unique. Make sure there is no water in the conduit from the timer to the pump, and breaker to timer. Filter runs fine at first, but then eventually loses its umph and then the return becomes minimal. If all looks tight you may need a new Max-Flo II motor or a new Max-Flo XL pump. "publisher": {
The pump is only one year old. When the valve is positioned on the filter, it should slide over the standpipe tube, or the center pipe that is connected to the laterals will slide up into the bottom of the valve, and the valve is pushed down to make a tight fit against the filter flange, and then the clamp is supposed to hold it tightly. Or, soak them in a TSP solution (1 lb of TSP in 5 gals warm water), followed by a soaking in an acid solution, 1 gallon acid added to 4 gallons of water.